+7 (495) 215-15-16

XW6

Уменьшите размеры панелей управления и сохраните работу с помощью проводного интерфейса с видимым индикатором

Спецификации и заказ

AppearanceMaximum Conductor Cross Section Fine Stranded (mm?)Number of pinsColor of Short BarsWeight (g)Order code
1.58RedApprox. 16XW6T-COM1.5X8RD
BlueXW6T-COM1.5X8BL
YellowXW6T-COM1.5X8YL
12RedApprox. 23XW6T-COM1.5X12RD
BlueXW6T-COM1.5X12BL
YellowXW6T-COM1.5X12YL
16RedApprox. 29XW6T-COM1.5X16RD
BlueXW6T-COM1.5X16BL
YellowXW6T-COM1.5X16YL
20RedApprox. 36XW6T-COM1.5X20RD
BlueXW6T-COM1.5X20BL
YellowXW6T-COM1.5X20YL
40RedApprox. 68XW6T-COM1.5X40RD
BlueXW6T-COM1.5X40BL
YellowXW6T-COM1.5X40YL
2.58RedApprox. 28XW6T-COM2.5X8RD
BlueXW6T-COM2.5X8BL
YellowXW6T-COM2.5X8YL
12RedApprox. 41XW6T-COM2.5X12RD
BlueXW6T-COM2.5X12BL
YellowXW6T-COM2.5X12YL
16RedApprox. 53XW6T-COM2.5X16RD
BlueXW6T-COM2.5X16BL
YellowXW6T-COM2.5X16YL
20RedApprox. 65XW6T-COM2.5X20RD
BlueXW6T-COM2.5X20BL
YellowXW6T-COM2.5X20YL
40RedApprox. 126XW6T-COM2.5X40RD
BlueXW6T-COM2.5X40BL
YellowXW6T-COM2.5X40YL
AppearanceApplicable Terminal BlocksApplicationOrder code
XW6T-COM1.5X ????This is a Terminal Block for addition. By using it with Short Bars as a set, Addition of the common points is available. Always attach the end cover after addition to prevent electrical shock. (Refer to page 14 for details.)XW6T-COM1.5
XW6T-COM2.5X ????XW6T-COM2.5
AppearanceApplicable Terminal BlocksNumber of polesCovering colorApplicationOrder code 2 Replace the box ( ? ) in the model number with the code for the covering color. Selection of the box ( ? ): RD=Red, BL=Blue, YL=Yellow
XW6T-COM1.5X ????2Red (RD) Blue (BL) Yellow (YL)Used for crossover wiring between Terminal Blocks.XW5S-P1.5-2 ?
3XW5S-P1.5-3 ?
4XW5S-P1.5-4 ?
5XW5S-P1.5-5 ?
10XW5S-P1.5-10 ?
XW6T-COM2.5X ????2Red (RD) Blue (BL) Yellow (YL)XW5S-P2.5-2 ?
3XW5S-P2.5-3 ?
4XW5S-P2.5-4 ?
5XW5S-P2.5-5 ?
10XW5S-P2.5-10 ?
AppearanceApplicable Terminal BlocksApplicationOrder code
XW6T-COM1.5X ????This part is required to prevent electrical shock. Attach end covers for the Terminal Blocks before use on the following parts. (Refer to page 14 for details.) Exposed metal surface of the last Terminal Block Any Terminal Block that is next to a different shape of Terminal Blocks.XW6E-COM1.5
XW6T-COM2.5X ????XW6E-COM2.5
AppearanceWidth (mm)ApplicationOrder code
6End Brackets are installed on the both ends of the Terminal Blocks to prevent them from moving on DIN Track.XW5Z-EP6

Аксессуары (Заказываются отдельно)

AppearanceApplicable Terminal BlocksApplicationOrder code
XW6T-COM1.5X ????This is a Terminal Block for addition. By using it with Short Bars as a set, Addition of the common points is available. Always attach the end cover after addition to prevent electrical shock. (Refer to page 14 for details.)XW6T-COM1.5
XW6T-COM2.5X ????XW6T-COM2.5
AppearanceApplicable Terminal BlocksNumber of polesCovering colorApplicationOrder code 2 Replace the box ( ? ) in the model number with the code for the covering color. Selection of the box ( ? ): RD=Red, BL=Blue, YL=Yellow
XW6T-COM1.5X ????2Red (RD) Blue (BL) Yellow (YL)Used for crossover wiring between Terminal Blocks.XW5S-P1.5-2 ?
3XW5S-P1.5-3 ?
4XW5S-P1.5-4 ?
5XW5S-P1.5-5 ?
10XW5S-P1.5-10 ?
XW6T-COM2.5X ????2Red (RD) Blue (BL) Yellow (YL)XW5S-P2.5-2 ?
3XW5S-P2.5-3 ?
4XW5S-P2.5-4 ?
5XW5S-P2.5-5 ?
10XW5S-P2.5-10 ?
AppearanceApplicable Terminal BlocksApplicationOrder code
XW6T-COM1.5X ????This part is required to prevent electrical shock. Attach end covers for the Terminal Blocks before use on the following parts. (Refer to page 14 for details.) Exposed metal surface of the last Terminal Block Any Terminal Block that is next to a different shape of Terminal Blocks.XW6E-COM1.5
XW6T-COM2.5X ????XW6E-COM2.5
AppearanceWidth (mm)ApplicationOrder code
6End Brackets are installed on the both ends of the Terminal Blocks to prevent them from moving on DIN Track.XW5Z-EP6

(Дополнительно) Клеммный блок

AppearanceApplicable Terminal BlocksApplicationOrder code
XW6T-COM1.5X ????This is a Terminal Block for addition. By using it with Short Bars as a set, Addition of the common points is available. Always attach the end cover after addition to prevent electrical shock. (Refer to page 14 for details.)XW6T-COM1.5
XW6T-COM2.5X ????XW6T-COM2.5

Короткие стержни

AppearanceApplicable Terminal BlocksNumber of polesCovering colorApplicationOrder code 2 Replace the box ( ? ) in the model number with the code for the covering color. Selection of the box ( ? ): RD=Red, BL=Blue, YL=Yellow
XW6T-COM1.5X ????2Red (RD) Blue (BL) Yellow (YL)Used for crossover wiring between Terminal Blocks.XW5S-P1.5-2 ?
3XW5S-P1.5-3 ?
4XW5S-P1.5-4 ?
5XW5S-P1.5-5 ?
10XW5S-P1.5-10 ?
XW6T-COM2.5X ????2Red (RD) Blue (BL) Yellow (YL)XW5S-P2.5-2 ?
3XW5S-P2.5-3 ?
4XW5S-P2.5-4 ?
5XW5S-P2.5-5 ?
10XW5S-P2.5-10 ?

Торцевая крышка

AppearanceApplicable Terminal BlocksApplicationOrder code
XW6T-COM1.5X ????This part is required to prevent electrical shock. Attach end covers for the Terminal Blocks before use on the following parts. (Refer to page 14 for details.) Exposed metal surface of the last Terminal Block Any Terminal Block that is next to a different shape of Terminal Blocks.XW6E-COM1.5
XW6T-COM2.5X ????XW6E-COM2.5

Концевые скобки

AppearanceWidth (mm)ApplicationOrder code
6End Brackets are installed on the both ends of the Terminal Blocks to prevent them from moving on DIN Track.XW5Z-EP6
ModelXW6T-COM1.5X ????XW6T-COM2.5X ????
Applicable wire sizes 2 For the applicable wire ranges, refer to page 11 for solid and stranded wires and to page 13 for ferrules.Nominal cross section0.75 mm? (1.5 mm?) 2 You can also use ferrules for 1.0 to 1.5 mm? wires if you use ferrules without insulation sleeve.
Minimum conductor cross section solid0.14 mm?0.14 mm?
Maximum conductor cross section solid1.5 mm?4.0 mm?
Minimum conductor cross section fine stranded0.08 mm?0.14 mm?
Maximum conductor cross section fine stranded1.5 mm?2.5 mm?
Minimum conductor cross section (flex., stranded) with ferrule with plastic sleeve0.14 mm?0.14 mm?
Maximum conductor cross Section (flex., stranded) with ferrule with plastic sleeve0.75 mm? (1.5 mm?) 2 You can also use ferrules for 1.0 to 1.5 mm? wires if you use ferrules without insulation sleeve.2.5 mm?
DimensionsA x 78 x 31.3 (Dimension A...8 pins: 9.2, 12 pins: 12.7, 16 pins: 16.2, 20 pins: 19.7, 40 pins: 37.2)A x 82.6 x 36.1 (Dimension A...8 pins: 12.6, 12 pins: 17.8, 16 pins: 23.0, 20 pins: 28.2, 40 pins: 54.2)
IEC rated voltage500 V800 V
IEC rated current17.5 A/1.5 mm?24 A/2.5 mm?
Usage Group (UG)B, CD
UL rated voltage300 V51 to 150 V
UL rated current15 A/AWG14 (solid wires) 10 A/AWG1615 A/AWG14 (solid wires) 10 A/AWG16
Withstand voltage1,890 VAC for 1 min (leakage current: 1 mA max.)2,000 VAC for 1 min (leakage current: 1 mA max.)
End CoverXW6E-COM1.5XW6E-COM2.5
Special toolXW4Z-00BXW4Z-00B
Col1Col2
Ambient temperature range-40 to 55°C (with no condensation or icing)
Ambient humidity range5 to 95%RH
Insulating materialPA resin
Fire resistanceUL94 V-0
Insertion durability50 times
Vibration resistance10 to 150 Hz, Acceleration of 50 m/s? for 80 min each in X, Y, and Z directions.
Shock resistance500 m/s? for 11 ms each in 6 directions 5 times
Ambient storage temperature-40 to 85°C (with no condensation or icing)
Ambient storage humidity5 to 95%RH
ModelXW6T-COM1.5X ????XW6T-COM2.5X ????
Applicable wire sizes 2 For the applicable wire ranges, refer to page 11 for solid and stranded wires and to page 13 for ferrules.Nominal cross section0.75 mm? (1.5 mm?) 2 You can also use ferrules for 1.0 to 1.5 mm? wires if you use ferrules without insulation sleeve.
Minimum conductor cross section solid0.14 mm?0.14 mm?
Maximum conductor cross section solid1.5 mm?4.0 mm?
Minimum conductor cross section fine stranded0.08 mm?0.14 mm?
Maximum conductor cross section fine stranded1.5 mm?2.5 mm?
Minimum conductor cross section (flex., stranded) with ferrule with plastic sleeve0.14 mm?0.14 mm?
Maximum conductor cross Section (flex., stranded) with ferrule with plastic sleeve0.75 mm? (1.5 mm?) 2 You can also use ferrules for 1.0 to 1.5 mm? wires if you use ferrules without insulation sleeve.2.5 mm?
DimensionsA x 78 x 31.3 (Dimension A...8 pins: 9.2, 12 pins: 12.7, 16 pins: 16.2, 20 pins: 19.7, 40 pins: 37.2)A x 82.6 x 36.1 (Dimension A...8 pins: 12.6, 12 pins: 17.8, 16 pins: 23.0, 20 pins: 28.2, 40 pins: 54.2)
IEC rated voltage500 V800 V
IEC rated current17.5 A/1.5 mm?24 A/2.5 mm?
Usage Group (UG)B, CD
UL rated voltage300 V51 to 150 V
UL rated current15 A/AWG14 (solid wires) 10 A/AWG1615 A/AWG14 (solid wires) 10 A/AWG16
Withstand voltage1,890 VAC for 1 min (leakage current: 1 mA max.)2,000 VAC for 1 min (leakage current: 1 mA max.)
End CoverXW6E-COM1.5XW6E-COM2.5
Special toolXW4Z-00BXW4Z-00B
Col1Col2
Ambient temperature range-40 to 55°C (with no condensation or icing)
Ambient humidity range5 to 95%RH
Insulating materialPA resin
Fire resistanceUL94 V-0
Insertion durability50 times
Vibration resistance10 to 150 Hz, Acceleration of 50 m/s? for 80 min each in X, Y, and Z directions.
Shock resistance500 m/s? for 11 ms each in 6 directions 5 times
Ambient storage temperature-40 to 85°C (with no condensation or icing)
Ambient storage humidity5 to 95%RH