+7 (495) 215-15-16

GI-S Series

Клеммы ввода-вывода безопасности для CIP Safety(TM)

Спецификации и заказ

SpecificationsI/O capacityUnit versionOrder codeCommunication protocolNumber of connectorsNumber of networksSafety inputsPulse outputsSafety outputs (for PNP)
EtherNet/IP21 2 PORT1 and PORT2 are ports with switching hub.12 inputs12 outputs4 outputsVer. 1.2GI-SMD1624
-GI-SID1224
Certification bodyStandards
T?V RheinlandEN ISO 13849-1IEC 61508 parts 1-7IEC/EN 62061IEC/EN 61131-2
ULNRAQ (UL61010-1, and UL 61010-2-201)NRAG (UL 121201)NRAQ7 (CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201)
ItemSpecifications
EnclosureMounted in a panel (open type)
Operating environmentAmbient operating temperature
Ambient operating humidity10% to 95% (with no condensation or icing)
AtmosphereMust be free from corrosive gases
Ambient storage temperature?25 to 70°C (with no condensation or icing)
Altitude2,000 m max.
Pollution degree2
Insulation classCLASS III (SELV)
Overvoltage categoryII
EMC immunity levelZone B: IEC 61131-2
Vibration resistanceConforms to IEC 60068-2-6 5 to 8.4 Hz with amplitude of 3.5 mm 8.4 to 150 Hz, acceleration of 9.8 m/s 2 100 min. in each X, Y, and Z directions (10 sweeps of 10 min. each = 100 min. total)
Shock resistanceConforms to IEC 60068-2-27 147 m/s 2 3 times in each X, Y, and Z directions
Insulation resistance20 MOhm between isolated circuits (at 100 VDC)
Dielectric strength500 VAC between isolated circuits for 1 minute at a leakage current of 10 mA max.
Installation methodDIN Track mounting (IEC 60715 TH35-7.5/TH35-15)
Degree of protectionIP20
ModelGI-SMD1624GI-SID1224
Number of safety input points12
Number of safety output points4-
Number of test output points12
OMRON special safety input device 2 OMRON special safety input devices are the following input devices: - Safety mat UMA/UM - Safety edge SGE - Single-beam safety sensor E3ZS - Non-contact door switch D40A/D40ZConnection unavailable
LED indication[V0] LED, [IN ? ] LED x 12, [V1] LED, [OUT ? ] LED x 4, [MS] LED, [NS] LED, [PORT ? LINK] LED x 2[V0] LED, [IN ? ] LED x 12, [V1] LED, [MS] LED, [NS] LED, [PORT ? LINK] LED x 2
Hardware switch setting
Safety input typeIEC61131-2 type3 PNP (sinking inputs)
Safety input current6 mA max.
Safety input ON voltage11 VDC min.
Safety input OFF voltage/OFF current5 VDC max./1 mA max.
Safety output typeSource output (for PNP)
Safety output rated current0.5 A max.2 GI-SID1224 has no output signal terminal and no output power supply is connected.
Maximum total safety output current2.0 A
Safety output ON residual voltage1.2 V max. (between V1 and each output terminal)
Safety output OFF residual voltage2.0 V max. (between G1 and each output terminal)
Safety output leakage current0.1 mA max.
Test output typeSource output (for PNP)
Test output rated current0.7 A max.
Maximum total test output current5.0 A
Test output ON residual voltage1.2 V max. (between V0 and each output terminal)
Test output leakage current0.1 mA max.
External dimensions 2 Projections are not included.170 (W) x 65 (H) x 55 (D)
Weight400 g
Number of communications that can be set between NX Units254 ports max. 2 Projections are not included.
Unit power suppliesPower supply voltage24 VDC (20.4 to 28.8 VDC)
Current consumption 2 Inrush current when the supply power is turned ON from the static power-OFF state. Inrush current value may vary depending on conditions. For your selection of fuses, breakers, and external power supply units, take into account the conditions to be used to select those that have a margin in characteristics and capacity.250 A max.
Inrush currentOn cold start at normal temperature50 A max., 0.1 ms max.
Power supply terminal current carrying capacity 2 Current-carrying capacity allowed to continuously flow through the terminal. This current must not be exceeded in case crossover wiring is done for the unit power supply.5 A
Insulation typeNo insulation: Between unit power supply terminal and internal circuit
Output power supplyPower supply voltage24 VDC (20.4 to 28.8 VDC)
Current consumption50 A max.
Inrush currentOn cold start at normal temperature 50 A max., 0.1 ms max.
Power supply terminal current carrying capacity 2 Current-carrying capacity allowed to continuously flow through the terminal. This current must not be exceeded in case crossover wiring is done for the unit power supply.5 A
Insulation typePhotocoupler insulation
External connection terminalCommunication connectorEtherNet/IP communication RJ45 x 2
Screwless clamp terminal blockTop terminal block Functional earthing Unit power supply Input/Test output Bottom terminal block Output power supply Output/Input/Test outputTop terminal block Functional earthing Unit power supply Input/Test output Bottom terminal block Input/Test output
Inter-terminal connection diagramV0/G0 Unit power supply
V1/G1 Output power supply2 GI-SID1224 has no output signal terminal and no output power supply is connected.
Installation direction and restrictionNo restriction
Protective functionOvervoltage protection, overcurrent protection
ItemSpecificationsGI-SMD1624 / GI-SID1224
Communications protocolTCP/IP, UDP/IP
Support servicesSysmac Studio connection, CIP message communication, DHCP (client)
Number of logical ports2
Physical layer100BASE-TX
Transmission specificationsMedia access methodCSMA/CD
ModulationBaseband
Transmission pathStar, daisy chain, mixed (star and daisy chain)
Transmission rate100M bit/s (100BASE-TX)
Transmission mediaTwisted-pair cable (shielded: STP): category 5/5e or higher
Transmission distance100 m max. (distance between hub and node)
Number of daisy chain connections8 units
CIP messaging service: Explicit message UCMM (non-connection type)Maximum number of clients that can communicate simultaneously: 8/Logical ports
Implicit (I/O) connectionExclusive Owner (EO) connection1
EtherNet/IP conformance testCT9 compliant
Ethernet interface100BASE-TX Auto Negotiation Auto-MDI
Safety I/O terminalCorresponding unit version/versionModelUnit versionSafety CPU Unit NX-SL5700 NX-SL5500Communication Control Unit NX-CSG320Machine Automation Controller NX102- ????Sysmac Studio
GI-SMD1624Ver. 1.2Ver. 1.3Ver. 1.01Ver. 1.31Ver. 1.24
GI-SID1224Ver. 1.2Ver. 1.3Ver. 1.01Ver. 1.31Ver. 1.24

Правила и стандарты

Certification bodyStandards
T?V RheinlandEN ISO 13849-1IEC 61508 parts 1-7IEC/EN 62061IEC/EN 61131-2
ULNRAQ (UL61010-1, and UL 61010-2-201)NRAG (UL 121201)NRAQ7 (CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201)

Клеммы ввода/вывода безопасности серии GI-S

Протокол FSoE сертифицирован для приложений, в которых устройства OMRON FSoE подключаются друг к другу. Для совместимости с устройствами FSoE, отличными от устройств OMRON FSoE, заказчик должен проверить связь FSoE. Кроме того, клеммы ввода-вывода безопасности серии GI-S были зарегистрированы на соответствие RCM, EAC и KC (корейский регламент радиосвязи).

Certification bodyStandards
T?V RheinlandEN ISO 13849-1IEC 61508 parts 1-7IEC/EN 62061IEC/EN 61131-2
ULNRAQ (UL61010-1, and UL 61010-2-201)NRAG (UL 121201)NRAQ7 (CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201)

Общие характеристики

ItemSpecifications
EnclosureMounted in a panel (open type)
Operating environmentAmbient operating temperature
Ambient operating humidity10% to 95% (with no condensation or icing)
AtmosphereMust be free from corrosive gases
Ambient storage temperature?25 to 70°C (with no condensation or icing)
Altitude2,000 m max.
Pollution degree2
Insulation classCLASS III (SELV)
Overvoltage categoryII
EMC immunity levelZone B: IEC 61131-2
Vibration resistanceConforms to IEC 60068-2-6 5 to 8.4 Hz with amplitude of 3.5 mm 8.4 to 150 Hz, acceleration of 9.8 m/s 2 100 min. in each X, Y, and Z directions (10 sweeps of 10 min. each = 100 min. total)
Shock resistanceConforms to IEC 60068-2-27 147 m/s 2 3 times in each X, Y, and Z directions
Insulation resistance20 MOhm between isolated circuits (at 100 VDC)
Dielectric strength500 VAC between isolated circuits for 1 minute at a leakage current of 10 mA max.
Installation methodDIN Track mounting (IEC 60715 TH35-7.5/TH35-15)
Degree of protectionIP20

ГИ-СМД1624/ГИ-СИД1224

ModelGI-SMD1624GI-SID1224
Number of safety input points12
Number of safety output points4-
Number of test output points12
OMRON special safety input device 2 OMRON special safety input devices are the following input devices: - Safety mat UMA/UM - Safety edge SGE - Single-beam safety sensor E3ZS - Non-contact door switch D40A/D40ZConnection unavailable
LED indication[V0] LED, [IN ? ] LED x 12, [V1] LED, [OUT ? ] LED x 4, [MS] LED, [NS] LED, [PORT ? LINK] LED x 2[V0] LED, [IN ? ] LED x 12, [V1] LED, [MS] LED, [NS] LED, [PORT ? LINK] LED x 2
Hardware switch setting
Safety input typeIEC61131-2 type3 PNP (sinking inputs)
Safety input current6 mA max.
Safety input ON voltage11 VDC min.
Safety input OFF voltage/OFF current5 VDC max./1 mA max.
Safety output typeSource output (for PNP)
Safety output rated current0.5 A max.2 GI-SID1224 has no output signal terminal and no output power supply is connected.
Maximum total safety output current2.0 A
Safety output ON residual voltage1.2 V max. (between V1 and each output terminal)
Safety output OFF residual voltage2.0 V max. (between G1 and each output terminal)
Safety output leakage current0.1 mA max.
Test output typeSource output (for PNP)
Test output rated current0.7 A max.
Maximum total test output current5.0 A
Test output ON residual voltage1.2 V max. (between V0 and each output terminal)
Test output leakage current0.1 mA max.
External dimensions 2 Projections are not included.170 (W) x 65 (H) x 55 (D)
Weight400 g
Number of communications that can be set between NX Units254 ports max. 2 Projections are not included.
Unit power suppliesPower supply voltage24 VDC (20.4 to 28.8 VDC)
Current consumption 2 Inrush current when the supply power is turned ON from the static power-OFF state. Inrush current value may vary depending on conditions. For your selection of fuses, breakers, and external power supply units, take into account the conditions to be used to select those that have a margin in characteristics and capacity.250 A max.
Inrush currentOn cold start at normal temperature50 A max., 0.1 ms max.
Power supply terminal current carrying capacity 2 Current-carrying capacity allowed to continuously flow through the terminal. This current must not be exceeded in case crossover wiring is done for the unit power supply.5 A
Insulation typeNo insulation: Between unit power supply terminal and internal circuit
Output power supplyPower supply voltage24 VDC (20.4 to 28.8 VDC)
Current consumption50 A max.
Inrush currentOn cold start at normal temperature 50 A max., 0.1 ms max.
Power supply terminal current carrying capacity 2 Current-carrying capacity allowed to continuously flow through the terminal. This current must not be exceeded in case crossover wiring is done for the unit power supply.5 A
Insulation typePhotocoupler insulation
External connection terminalCommunication connectorEtherNet/IP communication RJ45 x 2
Screwless clamp terminal blockTop terminal block Functional earthing Unit power supply Input/Test output Bottom terminal block Output power supply Output/Input/Test outputTop terminal block Functional earthing Unit power supply Input/Test output Bottom terminal block Input/Test output
Inter-terminal connection diagramV0/G0 Unit power supply
V1/G1 Output power supply2 GI-SID1224 has no output signal terminal and no output power supply is connected.
Installation direction and restrictionNo restriction
Protective functionOvervoltage protection, overcurrent protection

Характеристики встроенного порта EtherNet/IP

В этом разделе описаны характеристики полевой шины терминала безопасности ввода-вывода.

ItemSpecificationsGI-SMD1624 / GI-SID1224
Communications protocolTCP/IP, UDP/IP
Support servicesSysmac Studio connection, CIP message communication, DHCP (client)
Number of logical ports2
Physical layer100BASE-TX
Transmission specificationsMedia access methodCSMA/CD
ModulationBaseband
Transmission pathStar, daisy chain, mixed (star and daisy chain)
Transmission rate100M bit/s (100BASE-TX)
Transmission mediaTwisted-pair cable (shielded: STP): category 5/5e or higher
Transmission distance100 m max. (distance between hub and node)
Number of daisy chain connections8 units
CIP messaging service: Explicit message UCMM (non-connection type)Maximum number of clients that can communicate simultaneously: 8/Logical ports
Implicit (I/O) connectionExclusive Owner (EO) connection1
EtherNet/IP conformance testCT9 compliant
Ethernet interface100BASE-TX Auto Negotiation Auto-MDI

Информация о версии

В этом разделе описаны комбинации, которые можно использовать из версий модуля безопасности и модуля управления связью, контроллера автоматизации оборудования и версии Sysmac Studio.

Safety I/O terminalCorresponding unit version/versionModelUnit versionSafety CPU Unit NX-SL5700 NX-SL5500Communication Control Unit NX-CSG320Machine Automation Controller NX102- ????Sysmac Studio
GI-SMD1624Ver. 1.2Ver. 1.3Ver. 1.01Ver. 1.31Ver. 1.24
GI-SID1224Ver. 1.2Ver. 1.3Ver. 1.01Ver. 1.31Ver. 1.24